A modified direct-current voltage-gradient (DCVG) survey technique is now in use that appears to provide pipe-to-soil potentials that compare well with those from the traditional CIPS method but with less labor and greater precision.Pipe-to-soil potentials measured against a reference electrode are a commonly used indicator to control pipe line cathodic protection. A trailing cable usually is necessary and the potentials are measured along the whole pipe line by taking readings at regular intervals or at the epicenter of coating faults pinpointed with the DCVG technique. This article considers epicenter pipe-to-soil potentials measured by means of a modified DCVG technique, without trailing cable.
机译:现在正在使用一种改进的直流电压梯度(DCVG)测量技术,该技术似乎可以提供与传统CIPS方法相比很好的管道到土壤电势,但劳动量少且精度更高。针对参比电极测得的电位是控制管道阴极保护的常用指示器。通常必须使用拖曳电缆,并且通过以规则的时间间隔或在DCVG技术确定的涂层故障的震中读取读数来测量整个管道的电位。本文考虑了通过改进的DCVG技术在没有拖尾电缆的情况下测得的震中管道到土壤的电势。