OBJECTIVE: This study aimed to challenge the classical hypothesis that a negative preoperative 512-Hz Rinne tuning fork test (bone conduction greater than air conduction) is a necessary condition to allow consistent objective and subjective hearing improvement with surgery for otosclerosis. STUDY DESIGN: The study design was retrospective (chart review and questionnaire). SETTING: The study was conducted at a Florida Ear and Sinus Center at Sarasota, Florida, a tertiary otology-neurotology referral center. PATIENTS: Patients who underwent primary laser stapedotomy with equivocal (air=bone) preoperative 512-Hz Rinne test results participated. INTERVENTION: KTP laser stapedotomy was performed. MAIN OUTCOME MEASURES: Audiologic measurements of air-bone gap closure and patient assessment of hearing improvement and satisfaction were conducted. RESULTS: The air-bone gap was closed to within 10 dB in all cases. There were no complications. Eighteen patients were questioned about their results. Hearing improvement was subjectively described as "excellent" or "good" by 17 (94%), and 16 (89%) thought the surgery was "absolutely" worthwhile. CONCLUSIONS: The preoperative 512-Hz Rinne test results need not be negative to achieve significant air-bone gap closure and subjective appreciation of improved hearing.
机译:目的:本研究旨在挑战经典的假设,即术前512 Hz Rinne音叉试验阴性(骨传导大于空气传导)是使耳硬化症患者客观和主观听力得到持续改善的必要条件。研究设计:研究设计是回顾性的(图表审查和问卷调查)。地点:该研究在佛罗里达州萨拉索塔的佛罗里达耳鼻窦中心进行,该中心是第三耳科-神经内科转诊中心。患者:接受原发性激光ped骨切开术,并在手术前进行了模棱两可的(空气=骨骼)512 Hz Rinne测试结果的患者。干预:行KTP激光骨切开术。主要观察指标:进行空气间隙闭合的听力学测量以及患者听力改善和满意度的评估。结果:在所有情况下,气隙均保持在10 dB以内。没有并发症。询问了18名患者的结果。听力改善被主观描述为“优秀”或“良好”的有17位(占94%),有16位受访者(占89%)认为手术“绝对”值得。结论:术前512 Hz Rinne测试结果不必为阴性,以实现明显的气隙闭合和主观欣赏,可改善听力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号