...
首页> 外文期刊>Journal of cataract and refractive surgery >Effect of anterior capsule polishing on the posterior capsule opacification-inhibiting properties of a sharp-edged, 3-piece, silicone intraocular lens: three- and 5-year results of a randomized trial.
【24h】

Effect of anterior capsule polishing on the posterior capsule opacification-inhibiting properties of a sharp-edged, 3-piece, silicone intraocular lens: three- and 5-year results of a randomized trial.

机译:前囊抛光对锋利的三片式硅胶人工晶状体的后囊混浊抑制特性的影响:一项随机试验的三年和五年结果。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: To evaluate the long-term effects of anterior capsule polishing on regeneratory posterior capsule opacification (PCO), anterior capsule opacification (ACO), and fibrotic PCO with a silicone intraocular lens (IOL) with sharp optic edges. SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: This prospective bilateral randomized patient- and examiner-masked clinical trial comprised 130 eyes of 65 patients with bilateral age-related cataract. All eyes had implantation of a 3-piece silicone IOL with a truncated, sharp-edged optic (CeeOn Edge 911A, Advanced Medical Optics). In 1 eye, the anterior capsule was extensively polished using an aspiration curette after phacoemulsification and cortex aspiration. Regenerative PCO was quantified objectively, while ACO and fibrotic PCO were graded subjectively 1, 2, 3, and 5 years postoperatively. RESULTS: The mean ACO score was significantly lower in the eyes in which the anterior capsule had been polished (1 year, P<.02; 2 years, P<.03; 3 years, P<.01; 5 years, P<.01). The mean difference in regeneratory PCO and fibrotic PCO scores between the 2 groups was not statistically significant. CONCLUSIONS: Three years after cataract surgery, eyes in which the anterior capsule had been polished had significantly less ACO. However, polishing did not lower PCO intensity when a sharp-edged CeeOn 911A IOL was implanted in the bag. Although results indicate that anterior capsule polishing may enhance the development of regeneratory PCO, this trend did not reach statistical significance.
机译:目的:评估前囊膜抛光对再生性后囊膜混浊(PCO),前囊膜混浊(ACO)和纤维化PCO的长期影响,其硅树脂人工晶状体(IOL)具有清晰的光学边缘。地点:奥地利维也纳医科大学眼科。方法:这项前瞻性双边随机患者和检查员掩盖的临床试验由65例双侧年龄相关性白内障患者的130只眼组成。所有眼睛均植入了三件式硅树脂人工晶体,并带有截短的,锋利的镜片(CeeOn Edge 911A,高级医疗光学)。在一只眼睛中,在超声乳化和皮质抽吸后,使用抽吸刮匙将前囊充分抛光。客观评估再生PCO,而术后1、2、3和5年对ACO和纤维化PCO进行主观分级。结果:前囊被磨光的眼睛的平均ACO得分明显较低(1年,P <.02; 2年,P <.03; 3年,P <.01; 5年,P < .01)。两组之间的再生PCO和纤维化PCO评分的平均差异无统计学意义。结论:白内障手术三年后,前囊被抛光的眼睛的ACO明显减少。但是,将锐利的CeeOn 911A IOL植入袋中时,抛光并不会降低PCO强度。尽管结果表明前囊抛光可增强再生性PCO的发展,但这种趋势并未达到统计学意义。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号