The unbalanced magnetic pull (UMP) in a three-phase generator under no-load, caused by dynamic and static eccentricity, is calculated theoretically. The air-gap permeance is expressed as a Fourier series. Analytical expressions of the UMP for any pole-pair number are obtained. Effects of relative eccentricity and pole number on the magnitude of the UMP are obtained. The vibration of a model rotor in a three-phase generator under the action of the UMP and the eccentric force is analyzed by the numerical method and the harmonic analysis. (C) 2002 Elsevier Science Ltd. All rights reserved. [References: 15]
机译:理论上计算了由于动静偏心引起的三相发电机空载时的不平衡磁拉力(UMP)。气隙渗透率表示为傅立叶级数。获得了任意极对数的UMP的解析表达式。获得了相对偏心率和极数对UMP大小的影响。通过数值方法和谐波分析,分析了UMP和偏心力作用下三相发电机中模型转子的振动。 (C)2002 Elsevier ScienceLtd。保留所有权利。 [参考:15]