The present communication reports a rare cause of a type II endoleak in a patient treated for an isolated internal iliac artery (IIA) aneurysm. A 70-year-old patient underwent open surgical aortobiiliac graft placement in 1995. On follow-up computed tomographic (CT) angiography in 2005, the patient was found to have a type I right IIA aneurysm 94 X 91 mm in size, with its origin commencing at the bifurcation of the IIA (neck diameter measuring 8 mm) to involve the posterior and anterior divisions. This was embolized with an AMPLATZER Vascular Plug (AGA Medical, Golden Valley, Minnesota) and coils within the distal IIA and its branches, followed by an 18-mm X 55-mm Zenith stent-graft (Cook, Cork, Ireland) deployed in the right common iliac artery, across the orifice of the IIA.
机译:本来文报道了在治疗孤立的internal内动脉(IIA)动脉瘤的患者中,II型内漏的罕见原因。一名70岁的患者在1995年接受了开放式手术主动脉双胆移植。在2005年进行的后续计算机断层扫描(CT)血管造影检查中,发现该患者的I型右IIA动脉瘤大小为94 X 91 mm,起源于IIA的分叉处(颈部直径为8 mm),涉及后部和前部。用AMPLATZER血管塞(明尼苏达州金谷市的AGA Medical)和IIA远端及其分支内的线圈进行栓塞,然后将18毫米X 55毫米Zenith支架植入物(库克,科克,爱尔兰)进行栓塞。右common总动脉,穿过IIA孔。