首页> 外文期刊>Comparative Medicine >The ex vivo pig eye as a replacement model for laser safety testing
【24h】

The ex vivo pig eye as a replacement model for laser safety testing

机译:离体猪眼作为激光安全性测试的替代模型

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this study was to evaluate the viability of ex vivo pig eyes as a replacement model for in vivo testing in the establishment of laser eye safety standards. Previous studies of pulsed energy absorption at 3.8 microm were performed using rhesus monkey cornea at pulse durations two orders of magnitude shorter than the 8-micros pulses used in the current study. Ex vivo pig eyes were exposed to laser pulses of various energies and then evaluated to establish the statistical threshold for corneal damage. Tissue analysis (histologic evaluation) was used to determine the extent of damage to the cornea. These results can be used in the establishment of safety standards for laser use; our findings also suggest that ex vivo pig eyes are suitable models for this purpose.
机译:这项研究的目的是评估体外猪眼作为建立激光眼安全标准的体内测试替代模型的生存能力。使用恒河猴角膜以3.8微米的脉冲能量吸收进行了先前的研究,脉冲持续时间比当前研究中使用的8微米脉冲短两个数量级。离体猪眼暴露于各种能量的激光脉冲中,然后进行评估以建立角膜损伤的统计阈值。组织分析(组织学评估)用于确定对角膜的损害程度。这些结果可用于建立激光使用的安全标准。我们的发现还表明,离体猪眼是适合此目的的模型。