Randomized, double-masked clinical trial evaluating corneal endothelial cell loss after cataract extraction and intraocular lens implantation: Fluid-based system versus ultrasound phacoemulsification.

机译:评估白内障摘除和人工晶状体植入后角膜内皮细胞损失的随机,双掩盖临床试验:基于液的系统与超声超声乳化术。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To assess the endothelial cell loss after cataract extraction using a fluid-based system and compare it with conventional ultrasound. METHODS: A total of 46 eyes of 23 patients with up to 3+ bilateral cataract were included. The first eye was randomized to either fluid-based system or conventional ultrasound, and the fellow eye received the alternate system. Visual acuity and ultrasound pachymetry were measured preoperatively and at 1 day, 1 week, and 1 and 3 months postoperatively. Specular microscopy was performed preoperatively and 3 months after the surgery. Data was analyzed using the paired t test and Wilcoxon signed rank test. A P value less than 0.05 was considered statistically significant. RESULTS: Postoperatively, no significant differences were found among the groups. However, there was a significant difference (P < 0.01, analysis of variance with Tukey as posttest) in corneal pachymetry at day 1 after the surgery compared with baseline in both groups. There was a 6.3% and 7.9% loss of endothelial cells in the fluid-based system and ultrasound group, respectively. CONCLUSION: Visual acuity, pachymetry, and endothelial cell loss after cataract extraction and intraocular lens implantation using a fluid-based system is similar to conventional ultrasound.
机译:目的:评估使用基于液压系统的白内障摘除后内皮细胞的损失,并将其与常规超声进行比较。方法:共纳入23例双侧白内障3+患者的46只眼。第一只眼睛被随机分配到基于流体的系统或常规超声检查中,另一只眼睛接受了另一种系统。术前和术后1天,1周以及1和3个月测量视力和超声测厚法。术前和手术后3个月进行镜检镜检查。使用配对t检验和Wilcoxon符号秩检验对数据进行分析。 P值小于0.05被认为具有统计学意义。结果:术后两组之间无明显差异。然而,与基线相比,两组术后第1天角膜测厚法存在显着差异(P <0.01,用Tukey作为后验方差分析)。液基系统和超声治疗组的内皮细胞损失分别为6.3%和7.9%。结论:使用基于流体的系统进行白内障摘除和人工晶状体植入后的视敏度,测厚法和内皮细胞损失与常规超声相似。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号