...
首页> 外文期刊>COPD: Journal of Chronic Obstructive Pulmonary Disease >Accuracy of three activity monitors in patients with chronic obstructive pulmonary disease: A comparison with video recordings
【24h】

Accuracy of three activity monitors in patients with chronic obstructive pulmonary disease: A comparison with video recordings

机译:三种慢性阻塞性肺疾病患者活动监测仪的准确性:与视频记录的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Low physical activity and sedentary behaviour characterise the lives of patients with chronic obstructive pulmonary disease (COPD). Using activity monitors, assessment of both aspects are possible, but many outcomes are not well validated. The aim of this study was to assess the accuracy and equivalency of three activity monitors regarding steps, body position and their ability to differentiate between periods of physical activity and inactivity. Fifteen patients with COPD (8 females; median (interquartile range, IQR) age, 64 (59-69) years; forced expiratory volume in 1 second, 37 (28-48)% predicted; 6-minute walk distance, 444 (410-519) m) were enrolled. The DynaPort ADLmonitor, the DynaPort MiniMod monitor and the SenseWear Armband Pro 3 monitor were assessed. Subjects performed a structured protocol alternating physical activity and inactivity while simultaneously wearing all three monitors and being video recorded. The mean difference (limits of agreement) in step count from monitors compared to manual step count was-69 (-443 to 305) for the ADL-monitor,-19 (-141 to 103) for the MiniMod and-479 (-855 to-103) for the SenseWear Armband. Compared to the video, the sitting time was 97 (94-100)% when measured by the ADL-monitor and 121 (110-139)% by the MiniMod. Standing time was 114 (107-122)% when measured by the ADL-monitor and 68 (47-106)% by the MiniMod. Activity monitors are not equivalent in their abilities to detect steps or body positions. The choice of monitor should be based on the particular outcome of interest.
机译:低体力活动和久坐行为是慢性阻塞性肺疾病(COPD)患者生活的特征。使用活动监视器,可以对这两个方面进行评估,但是许多结果尚未得到很好的验证。这项研究的目的是评估关于步骤,身体位置及其区分身体活动和不活动时期的能力的三个活动监视器的准确性和等效性。 15例COPD患者(8名女性;中位(四分位间距,IQR)年龄,64(59-69)岁;强制呼气量1秒,预计37%(28-48); 6分钟步行距离,444(410) -519)m)被招募。评估了DynaPort ADLmonitor,DynaPort MiniMod显示器和SenseWear Armband Pro 3显示器。受试者执行结构化协议,交替进行体育活动和不运动,同时同时佩戴所有三个监视器并进行视频录制。监视器的步数与手动步数相比,ADL监视器的平均差(一致性极限)为-69(-443至305),MiniMod和-479(-855)为-19(-141至103)。到103)。与视频相比,通过ADL显示器测量的坐姿时间为97(94-100)%,通过MiniMod测量的坐姿时间为121(110-139)%。通过ADL显示器测量的站立时间为114(107-122)%,通过MiniMod测量为68(47-106)%。活动监视器在检测步伐或身体位置方面的能力并不相同。监控器的选择应基于感兴趣的特定结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号