Radio-opacity and incidental identified mechanical complications of totally implantable venous access devices placed in the chest.

机译:射线不透性和偶然发现的放置在胸部的完全可植入静脉通路装置的机械并发症。

获取原文
获取原文并翻译 | 示例
           

摘要

Background Totally implantable venous access devices (TIVAD) may be associated with different complications. Certain mechanical port disorders can easily be diagnosed on chest radiographs if the implanted systems are radiopaque and well visible. There are no reports regarding the visibility of TIVAD on chest X-rays. Purpose To assess the radio opacity of TIVAD implanted in the chest as well as type and frequency of mechanical complications of ports on chest X-ray images. Material and Methods Chest X-rays of 985 patients from the time period 2007-2009 were analyzed retrospectively. In these patients 1190 TIVAD were inserted. All parts of the TIVAD, i.e. port chamber, connection, and port catheter, were checked for their visibility on chest radiographs. An opacity score was used here as follows: ++ well visible; + visible; - partly or completely invisible. Mechanical complications of TIVAD incidentally detected on chest X-ray were also analyzed retrospectively. Results Nineteen TIVAD models with diverse configuration and visibility of port chambers, connections, and catheters were identified in our study. Eighty-eight percent of the analyzed port systems were well visible or visible on chest radiographs. Twelve percent of the port chambers and catheters were partly visible or completely invisible. In 9% of the TIVAD, different mechanical complications were diagnosed on chest X-ray images. Conclusion TIVADs should be evaluated carefully on every chest X-ray. Ideally, they should be radio-opaque and well visible on thoracic X-ray images. Unfortunately, this is not always the case. Therefore, manufacturers of TIVAD should take into consideration to use exclusively radio-opaque materials that allow sufficient visibility of each port component on chest radiographs.
机译:背景技术完全可植入的静脉通路装置(TIVAD)可能与不同的并发症有关。如果植入的系统是不透射线的且可见度很高,则可以很容易地在胸部X光片上诊断出某些机械端口异常。目前尚无有关TIVAD在胸部X光片上能见度的报道。目的评估植入胸部的TIVAD的射线不透性以及胸部X射线图像上端口机械并发症的类型和频率。材料与方法回顾性分析了2007年至2009年间985例患者的胸部X光片。在这些患者中,插入了1190个TIVAD。在胸部X光片上检查TIVAD的所有部分,即端口室,连接和端口导管。此处使用不透明度得分:++清晰可见; +可见; -部分或完全不可见。还回顾性分析了胸部X光检查偶然发现的TIVAD的机械并发症。结果在我们的研究中,确定了19个TIVAD模型,这些模型具有不同的配置以及对端口腔,连接和导管的可见性。在被分析的端口系统中,有88%清晰可见或在胸部X光片上可见。百分之十二的端口腔室和导管部分可见或完全不可见。在9%的TIVAD中,在胸部X射线图像上诊断出不同的机械并发症。结论应在每次胸部X线检查中仔细评估TIVAD。理想情况下,它们应该是不透射线的并且在胸部X射线图像上清晰可见。不幸的是,并非总是如此。因此,TIVAD的制造商应考虑仅使用不透射线的材料,以使胸部X光片上的每个端口组件具有足够的可见性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号