首页> 外文期刊>Experimental and therapeutic medicine >Intraoperative defibrillation threshold testing and postoperative long-term efficacy of cardioverter-defibrillator implantation
【24h】

Intraoperative defibrillation threshold testing and postoperative long-term efficacy of cardioverter-defibrillator implantation

机译:术中除颤阈值测试和心脏除颤器植入的术后长期疗效

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study was to determine the defibrillation threshold (DFT) of implantable cardioverter-defibrillators (ICDs) and outcomes of treatment. Sixty-four patients received cardioverter-defibrillator implantation. During implantation, the DFT was determined by the defibrillation safety margin (DSM). All patients were followed up for 12-48 months after the implantation. The overall DFT was 14.27 +/- 2.56 J and the DSM was 18.40 +/- 1.89 J. Malignant ventricular arrhythmias occurred in 42 patients following cardioverter-defibrillator implantation including 500 episodes of non-sustained ventricular tachycardia (VT) and 289 episodes of persistent VT. VT was treated using antitachycardia pacing (ATP); 265 episodes were treated successfully by a single ATP treatment (91.69%) and 12 episodes were treated successfully by two ATP treatments (4.15%). Twelve episodes were converted by low-energy electrical cardioversion (4.15%). A total of 175 ventricular fibrillation (VF) episodes were identified, of which 18 episodes automatically terminated prior to treatment. In total, 146 episodes were converted by a single cardioversion with a defibrillation energy of 13.21 +/- 2.58 J and 11 episodes were converted by two cardioversions with a defibrillation energy of 16.19 +/- 2.48 J. It is safe and feasible to determine the DFT by DSM measurement during cardioverter defibrillator implantation.
机译:本研究的目的是确定可植入的心脏除颤器(ICD)和治疗结果的除颤阈值(DFT)。六十四名患者接受了Cardioverter除颤器植入。在植入过程中,DFT由除颤安全裕度(DSM)确定。所有患者均在植入后12-48个月内随访。总体DFT为14.27 +/- 2.56J,DSM为18.40 +/- 1.89 J. 42例患者发生了42名患者,包括在Cardioverter除颤器植入后,包括500个非持续心室性心动过速(VT)和289个持续发作vt。使用抗斑节膜起搏(ATP)进行治疗vt;通过单个ATP处理成功处理265个发作(91.69%),并通过两次ATP处理成功处理12个发作(4.15%)。通过低能量电气心致(4.15%)转换十二集。鉴定了总共175个心室纤维化(VF)发作,其中在治疗之前将18个发作自动终止。共有146个剧集通过单一的载烷基转换,单个载体转化为13.21 +/- 2.58 J和11个发作,通过两种卡磷,具有16.19 +/-2.48 J的除颤能量。它是安全的,可行的DSM测量在CardIoverter除颤器植入过程中的DFT。

著录项

  • 来源
  • 作者单位

    Xinjiang Med Univ Dept Cardiol Affiliated Hosp 1 Urumqi 830054 Xinjiang Peoples R China;

    Nanjing Command PLA Dept Cardiol Fuzhou Gen Hosp Fuzhou 350025 Peoples R China;

    Xinjiang Med Univ Dept Cardiol Affiliated Hosp 1 Urumqi 830054 Xinjiang Peoples R China;

    Xinjiang Med Univ Dept Cardiol Affiliated Hosp 1 Urumqi 830054 Xinjiang Peoples R China;

    Xinjiang Med Univ Dept Cardiol Affiliated Hosp 1 Urumqi 830054 Xinjiang Peoples R China;

    Xinjiang Med Univ Dept Cardiol Affiliated Hosp 1 Urumqi 830054 Xinjiang Peoples R China;

    Xinjiang Med Univ Dept Cardiol Affiliated Hosp 1 Urumqi 830054 Xinjiang Peoples R China;

    Xinjiang Med Univ Dept Cardiol Affiliated Hosp 1 Urumqi 830054 Xinjiang Peoples R China;

    Xinjiang Med Univ Dept Cardiol Affiliated Hosp 1 Urumqi 830054 Xinjiang Peoples R China;

    Xinjiang Med Univ Dept Cardiol Affiliated Hosp 1 Urumqi 830054 Xinjiang Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 治疗学;
  • 关键词

    implantable cardioverter-defibrillator; defibrillation threshold; ventricular arrhythmia;

    机译:植入式心脏病 - 除颤器;除颤阈值;室性心律失常;