Airborne and impact sound insulation between rooms are two relevant quantities in evaluating the acoustic performance of buildings. In this study we report the measurements of the apparent sound reduction index R' and normalized impact sound pressure level L-n' between rooms, one on top of the other. In the tests carried out, the horizontal separating element between the two spaces was formed by the ceiling (plaster layer), a beam and pot floor construction and floor covering (terrazzo floor or parquet), with no floating floor. Based on field measurement results, a mass law was obtained for the apparent weighted sound reduction index R-w' and for the weighted normalized impact sound pressure level L-n,L-w' for this type of separating floors between flats. A link can be seen between R' and L-n' versus frequency, and the sum of R-w' and L-n,L-w'. These results were then compared with those proposed in standards EN 12354. Parts 1 and 2 and the differences were analysed.
机译:房间之间的空气传播和撞击声隔离是评估建筑物声学性能的两个相关量。在这项研究中,我们报告了房间之间(一个在另一个之上)的视在降噪指数R'和归一化冲击声压水平L-n'的测量结果。在进行的测试中,两个空间之间的水平分隔元素是由天花板(灰泥层),梁和锅地板结构以及地板(水磨石地板或镶木地板)构成的,没有浮动地板。根据现场测量结果,对于这种类型的地板之间的分隔地板,获得了视在加权的减声指数R-w'和加权归一化的冲击声压级L-n,L-w'的质量定律。可以看到R'和L-n'与频率以及R-w'和L-n,L-w'之和之间的联系。然后将这些结果与标准EN 12354中提出的结果进行比较。分析了第1部分和第2部分的差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号