Radioisotope identification using an energy-weighted algorithm with a proof-of-principle radiation portal monitor based on plastic scintillators

机译:基于塑料闪烁体的基于塑料闪烁体的原则上的原则上的能量加权算法识别放射性同位素识别

获取原文
获取原文并翻译 | 示例
           

摘要

In this study, we validated the feasibility of an energy weighted algorithm that highlights a characteristic area including the Compton edge as a single peak in a proof-of-principle radiation portal monitor system with a plastic scintillator measuring 50 x 100 x 5 cm(3). We measured the energy weighted spectra with steel shielding and the dynamic movements of the Cs-137 and Co-60 sources. The results showed that the peak locations of each source could be identified under shielded or dynamic motion conditions, each within a maximum difference of 0.08 MeV.
机译:在这项研究中,我们验证了能量加权算法的可行性,该算法突出显示包括康普顿边缘的特征区域,作为原则上的原则上辐射门户监测系统中的单个峰值,塑料闪烁仪测量50×100 x 5 cm(3 )。 我们用钢屏蔽测量了能量加权光谱和CS-137和CO-60源的动态运动。 结果表明,每个源的峰值可以在屏蔽或动态运动条件下识别,每个源在0.08 meV的最大差异内。