Long-Term Stability of the Electronic Sensor Component of a Digital Pill System in Real-World Storage Settings

机译:现实世界存储设置中数字丸系统的电子传感器组件的长期稳定性

获取原文
获取原文并翻译 | 示例
           

摘要

Background: Digital pill systems comprise an ingestible sensor integrated into a gelatin capsule that overencapsulates medication allowing real-time measures of medication ingestion. These systems may improve the manner in which medication adherence can be assessed and supported. Objective: In this investigation, we tested the durability of the ingestible sensor as part of a clinical trial to measure the feasibility and acceptability of the system to measure adherence to once daily tenofovir disoproxil fumarate/emtricitabine (NCT03842436). Methods: Digital pills not dispensed during the study were stored in a pharmacy. Seventeen sensors were selected from digital pills stored for at least 12 months and activated in a simulated gastric environment. A radiofrequency spectrum analyzer and the reader device used in the clinical trial to capture ingestion events were used to measure activation of emitters. A passing evaluation was defined as an energized emitter within 30 minutes of immersion, ability to broadcast a signal for 10 minutes, and successful acquisition by the reader. Results: All ingestible sensors passed the stability test. Mean activation time in simulated gastric fluid was 3.33 minutes (SD = 1.47); emitters remained active for a mean of 47.72 minutes (SD = 1.78). These parameters matched guidelines defined in the ID-Cap system requirements for use in patients. Conclusions: Ingestible sensor components of the ID-Cap system were therefore stable after long-term storage.
机译:背景:数字药丸系统包括一个集成在明胶胶囊中的可摄取传感器,该胶囊过度包裹药物,允许实时测量药物摄取。这些系统可以改善药物依从性的评估和支持方式。目的:在本研究中,作为临床试验的一部分,我们测试了可摄取传感器的耐用性,以测量系统对每日一次的富马酸替诺福韦二丙酯/恩曲他滨(NCT03842436)依从性的可行性和可接受性。方法:研究期间未配药的数字药丸储存在药房中。从储存至少12个月并在模拟胃环境中激活的数字药丸中选择17个传感器。临床试验中使用了射频频谱分析仪和读取器设备来捕获摄入事件,用于测量发射器的激活情况。合格评估被定义为浸入水中30分钟内的通电发射器、10分钟内广播信号的能力,以及读者的成功捕获。结果:所有可摄取传感器均通过稳定性测试。模拟胃液中的平均激活时间为3.33分钟(SD=1.47);发射器保持活动状态的平均时间为47.72分钟(SD=1.78)。这些参数符合ID Cap系统要求中定义的用于患者的指南。结论:因此,ID-Cap系统的可摄取传感器组件在长期储存后是稳定的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号