首页> 外文期刊>British journal of ophthalmology >Agreement between frequency doubling perimetry and static perimetry in eyes with high tension glaucoma and normal tension glaucoma.
【24h】

Agreement between frequency doubling perimetry and static perimetry in eyes with high tension glaucoma and normal tension glaucoma.

机译:高眼压性青光眼和正常眼压性青光眼的倍频视野检查和静态视野检查之间的一致性。

获取原文
获取原文并翻译 | 示例
           

摘要

AIMS: To investigate the agreement in results between frequency doubling technology (FDT) and the conventional automated static perimeter in eyes with normal tension glaucoma (NTG) and high tension glaucoma (HTG). METHODS: 72 eyes of 36 patients, who had two or more experiences with the Humphrey field analyser (HFA) program C30-2, were examined with the screening C-20-1 program of FDT. The result of FDT at each of the 17 stimulus points was graded as one of four categories. 58 out of 76 test points of HFA were assigned to one of the 17 clusters corresponding to FDT test points. Each cluster was represented as the lowest (scotoma of HFA) or the highest (threshold of HFA) probability symbol of total deviation (TD) of the HFA test points included in the cluster. The agreement between scotoma/threshold of HFA and FDT results was evaluated for NTG and HTG. RESULTS: In a total of 65 eyes, the Spearman coefficients between the FDT and HFA (threshold/scotoma of HFA) were 0.599 and 0.515 (p<0.0001), respectively. In the HFA mean deviation matched 20 HTG eyes and 20 NTG eyes, the number of points with abnormal FDT results were 102 and 62 in eyes with HTG and NTG, respectively. The eyes with HTG had more abnormal FDT results than NTG eyes (p=0.0014, Mann-Whitney U test). The kappa coefficient between FDT and threshold of HFA in eyes with HTG and NTG was 0.288 and 0.520, respectively, and the agreement between FDT and scotoma of HFA was 0.480 and 0.439, respectively. CONCLUSIONS: The best agreement of the results of FDT and HFA was observed in eyes with NTG using threshold of HFA. The eyes with HTG showed lower agreement with more abnormal points in FDT results, which suggests enough sensitivity of FDT in eyes with NTG, and higher sensitivity of FDT in eyes with HTG.
机译:目的:研究在正常眼压性青光眼(NTG)和高眼压性青光眼(HTG)的眼中,倍频技术(FDT)与常规自动静态视野之间的结果一致性。方法:使用FDT筛查C-20-1程序检查了36位患者的72只眼睛,这些患者在汉弗莱场分析仪(HFA)程序C30-2中具有两次或更多次经验。 FDT在17个刺激点中的每个点上的结果均被归类为四个类别之一。将HFA的76个测试点中的58个分配给与FDT测试点相对应的17个群集之一。每个聚类表示为包含在聚类中的HFA测试点的总偏差(TD)的最低(HFA暗点)或最高(HFA阈值)概​​率符号。对于NTG和HTG,评估了暗疮/ HFA阈值与FDT结果之间的一致性。结果:在总共65只眼中,FDT和HFA(HFA的阈值/暗点)之间的Spearman系数分别为0.599和0.515(p <0.0001)。在HFA平均偏差匹配的20眼HTG眼和20眼NTG眼中,具有HTG和NTG眼的FDT结果异常的点数分别为102和62。 HTG眼的FDT结果异常多于NTG眼(p = 0.0014,Mann-Whitney U检验)。在HTG和NTG眼中,FDT与HFA​​阈值之间的kappa系数分别为0.288和0.520,FDT与HFA​​的深部吻合度分别为0.480和0.439。结论:使用HFA阈值在NTG眼中可以观察到FDT和HFA结果的最佳一致性。 HTG眼的FDT结果与异常点的一致性较低,这表明NTG眼中FDT的敏感性足够,HTG眼中FDT的敏感性较高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号