Electrocoagulation was investigated for the treatment of agro-industry wastewaters,namely,meat processing,cereal products,food beverages and abattoir.Initial studies were carried out to check the performance of each of the agro-industry wastewaters(in terms of COD removal).The total cost(including,electrical power consumed,chemicals and consumption of electrodes)of the treatment varied between 0.95 and 4.93 m~(-3).Abattoir wastewater resulted in higher COD removal of 85-86%.Subsequent studies were performed in details on the selected abattoir wastewater.Bipolar mild steel electrode gave higher soluble COD removal(82%).Likewise,percent soluble COD removal as a function of pH and conductivity confirmed no need of acidification and electrolyte addition.The coupling of electrocoagulation with flocculation process resulted in effective removal of organics(82% total COD removal),inorganics(with the exception of nitrogen),pathogen destruction and solids and turbidity removal.Thus,electrocoagulation-flocculation process can be envisaged as an effective treatment process for decontamination of agro-industry wastewaters.
机译:研究了电凝处理农业工业废水的方法,即肉类加工,谷物产品,食品饮料和屠宰场。进行了初步研究,以检查每种农业工业废水的性能(以去除COD的方式)。该处理的总成本(包括电耗,化学药品和电极消耗)在0.95至4.93 m〜(-3)之间变化。屠宰场废水导致较高的COD去除率达85-86%。随后进行了详细研究在选定的屠宰场废水上,双极软钢电极的可溶性COD去除率更高(82%)。同样,可溶性pH值和电导率的可溶性COD去除率也证实不需要酸化和添加电解质。电凝与絮凝过程耦合有效去除有机物(总COD去除率82%),无机物(氮除外),病原体破坏以及固体和浊度去除。可以将浓缩絮凝工艺设想为一种用于农业工业废水净化的有效处理工艺。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号