首页> 美国政府科技报告 >Strength Design of Reinforced Concrete Hydraulic Structures. Report 4. Load-Moment Characteristics of Reinforced Concrete Circular Conduits
【24h】

Strength Design of Reinforced Concrete Hydraulic Structures. Report 4. Load-Moment Characteristics of Reinforced Concrete Circular Conduits

机译:钢筋混凝土水工结构的强度设计。报告4.钢筋混凝土圆形管道的荷载 - 弯矩特性

获取原文

摘要

The effect of initial curvature on the trust-moment characteristics of reinforced concrete circular conduit sections was investigated. This study was undertaken since conduit sections built by the Corps of Engineers are often so sharply curved relative to their thicknesses that initial curvature effects might be significant. The effect of initial curvature was investigated through curved beam, Airy stress function, and nonlinear finite element analyses. In addition, three model conduits representative of Corps construction were instrumented and simultaneously loaded on eight equally spaced diameters. For the range of design variables investigated, the analytical and experimental results indicate that initial curvature has no statistical significant effects. Further testing will be needed to obtain a larger statistical sample and evaluate the effects of more extreme curvatures than studied in this report.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号