Abstract: A two chamber starved air incinerator was equipped with an emission control system for controlling the particulate, HCl, heavy metals and dioxins/furans emissions from a regional medical waste incinerator facility. The batch operation of the incinerator creates a wide variation of the flue gas temperatures and flow rates. The flue gas after cooling also contains unburned hydrocarbons besides the high moisture content. The daily startup and shutdown of the incinerator concomitant with the misunderstanding of the characteristics of the flue gas from the incineration operation has resulted in overhauling the system in less than three months. After the introduction of the Tesisorb, a cake modifying agent, and the modification of the system operation, the system is now in good operation. The characteristic of the incinerator operation as well as the performance of the emission control system is discussed. !5
机译:摘要:两室挨饿的空气焚烧炉装有排放控制系统,用于控制区域医疗废物焚化炉设施中的微粒,HCl,重金属和二恶英/呋喃排放。焚化炉的分批运行会导致烟气温度和流量发生很大变化。冷却后的烟道气除了水分含量高外,还含有未燃烧的碳氢化合物。焚化炉的日常启动和关闭,以及对焚烧操作产生的烟气特性的误解,导致在不到三个月的时间内对系统进行了大修。在引入Tesisorb(一种蛋糕改性剂)并进行系统操作的修改后,系统现在处于良好的运行状态。讨论了焚烧炉运行的特点以及排放控制系统的性能。 !5