首页> 外文期刊>Clinical ophthalmology >Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens
【24h】

Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens

机译:新型三焦点人工晶状体与多焦点人工晶状体的光路性能

获取原文
           

摘要

Purpose: The purpose of this study is to compare the optical characteristics of the novel PanOptix presbyopia-correcting trifocal intraocular lens (IOL) and the multifocal ReSTOR?+3.0?D IOL, through in vitro bench investigations. Methods: The optical characteristics of AcrySof? IQ PanOptix? (PanOptix) and AcrySof? IQ ReSTOR +3.0 D (ReSTOR +3.0 D) IOLs were evaluated by through-focus Badal images, simulated headlight images, and modulation transfer function (MTF) measurements which determine resolution, photic phenomena, and image quality. Through-focus Badal images of an Early Treatment of Diabetic Retinopathy Study chart were recorded at both photopic and mesopic pupil sizes. Simulated headlight images were taken on an MTF bench with a 50-μm pinhole target and a 5.0 mm pupil at the distance focus of the IOL. MTF curves were measured with a 3.0 mm pupil, and spatial frequencies equivalent to 20/40 and 20/20 visual acuities were recorded to illustrate the through-focus MTF curves. Far-, intermediate-, and near-focus MTF values were obtained. Results: Bench Badal image testing and MTF measurements showed that PanOptix has a near focus at a distance of 42 cm and an additional intermediate focus at a distance of about 60 cm. The near focus for ReSTOR +3.0 D is at 45 cm. PanOptix and ReSTOR +3.0 D have comparable photopic distances and near MTF values. Additionally, PanOptix provided a substantial continuous range of vision from distance to intermediate and to near compared with ReSTOR?+3.0?D. The halo propensity for PanOptix was slightly higher than that for ReSTOR +3.0 D. Conclusion: Laboratory-based in vitro simulations showed that PanOptix trifocal IOL has comparable resolution and image quality performance in distance and near foci compared with ReSTOR +3.0 D IOL. PanOptix showed better resolution and image quality performance at the intermediate focus than ReSTOR +3.0 D IOL.
机译:目的:本研究的目的是通过体外实验研究,比较新型PanOptix矫正老花眼的三焦点人工晶状体(IOL)和多焦点ReSTOR?+3.0?D IOL的光学特性。方法:AcrySof ? IQ PanOptix?的光学特性(PanOptix)和AcrySof ? IQ ReSTOR +3.0 D(ReSTOR +3.0 D)IOL通过透焦Badal图像,模拟前灯图像和调制传递函数(MTF)测量来评估,这些测量可确定分辨率,光学现象和图像质量。糖尿病性视网膜病变早期治疗的全焦点Badal研究图记录在近视和中视瞳孔大小处。模拟的前灯图像是在MTF工作台上拍摄的,该工作台在IOL的距离焦点处具有50μm的针孔目标和5.0mm的瞳孔。使用3.0 mm瞳孔测量MTF曲线,并记录了相当于20/40和20/20视敏度的空间频率,以显示通过焦点的MTF曲线。获得了远,中和近焦点的MTF值。结果:Bench Badal图像测试和MTF测量表明PanOptix在42厘米的距离处具有近焦点,而在60厘米的距离处具有额外的中间焦点。 ReSTOR +3.0 D的近焦点在45厘米处。 PanOptix和ReSTOR +3.0 D具有可比的近视距离和接近MTF值。此外,与ReSTOR™+ 3.0™D相比,PanOptix提供了从远距离到中距离和近距离的相当连续的视觉范围。 PanOptix的晕圈倾向略高于ReSTOR +3.0 D的晕圈倾向。结论:基于实验室的体外模拟显示,与ReSTOR +3.0 D IOL相比,PanOptix三焦点IOL在远距离和近焦点处具有可比的分辨率和图像质量性能。与ReSTOR +3.0 D IOL相比,PanOptix在中间对焦时显示出更好的分辨率和图像质量性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号