...
首页> 外文期刊>The journal of maternal-fetal & neonatal medicine >Physical efficiency and activity energy expenditure in term pregnancy females measured during cardiopulmonary exercise tests with a supine cycle ergometer
【24h】

Physical efficiency and activity energy expenditure in term pregnancy females measured during cardiopulmonary exercise tests with a supine cycle ergometer

机译:仰卧循环测力计在心肺运动试验期间测量的足月妊娠女性的身体效率和活动能量消耗

获取原文
获取原文并翻译 | 示例
           

摘要

Objectives: To evaluate physical efficiency and activity energy expenditure (AEE) in term pregnancy females during cardiopulmonary exercise tests with a supine cycle ergometer.Material and methods: The study comprised 22 healthy full-term pregnancy women with uncomplicated pregnancies hospitalized in the Department of Gynecology and Obstetrics, Specialist Teaching Hospital in Tychy, Poland. All subjects underwent cardiopulmonary exercise tests (CPET) on a supine cycle ergometer. The 12-min, three-stage, progressive, symptom-limited submaximal test protocol (up to 80% HRmax) was used. Pulsometry was used to record HR on a beat-to-beat analysis and to calculate AEE. Respiratory responses were measured by ergospirometer and a computer system on a breath-by-breath basis at rest, during exercise and at restitution.Results: In the studied population, VO2max was established at the level of 2.190.33L/min in ergospirometry and 2.04 +/- 025L/min in pulsometry. Physical efficiency calculated for sub-maximal exercise by use of the Davis equation was 30.52 +/- 0.12%. AEE, based on VO2 in various phases of the CPET, was 0.47, 0.71 and 0.88L/min for phases 25, 50 and 75 W. Based on ergospirometer readouts, AEE was 10.60, 16.11 and 20.94kJ/min for phases 25, 50 and 75 W. Overall mean AEE (determined by pulsometry) was 10.59 kJ/min. CPET testing did not have any negative effect upon the health or life of the neonates involved in the study.Conclusions: Submaximal CPET up to 80% HRmax with a supine cycle ergometer is a safe and precise method for assessing work efficiency in term pregnancy women.
机译:目的:通过仰卧式自行车测功机评估足月妊娠妇女在心肺运动试验期间的身体效率和活动能量消耗(AEE)。材料和方法:该研究包括22例在妇产科住院的健康全程妊娠妇女,无并发症。波兰Tychy专科教学医院的妇产科。所有受试者均在仰卧周期测力计上进行心肺运动测试(CPET)。使用了12分钟,三阶段,进行性,症状受限的次最大试验方案(最大HRmax达到80%)。脉搏法用于在逐搏分析中记录心率并计算AEE。在休息,运动和恢复时,通过人体呼吸计和计算机系统对呼吸进行了呼吸测量。结果:在研究人群中,人体最大肺活量测定的最大摄氧量为2.190.33L / min,最高为2.04。脉搏计+/- 025L / min。使用戴维斯方程式计算的次最大运动量的身体效率为30.52 +/- 0.12%。在CPET各个阶段中,基于VO2的AEE在25、50和75 W阶段分别为0.47、0.71和0.88L / min。基于人体工学测试仪读数,在25、50阶段,AEE分别为10.60、16.11和20.94kJ / min。 75W。总体平均AEE(由脉搏测定法确定)为10.59 kJ / min。 CPET测试对本研究涉及的新生儿的健康或生命没有任何负面影响。结论:仰卧式周期测力计可将CPET降至HRmax低于80%,是评估足月妊娠妇女工作效率的安全,准确的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号