A generic biokinetic model was developed for use in the assessment of the internal dose received by human subjects injected with amino acids labelled with C-11 (T-1/2=0.34 h, beta(+), gamma), F-18(T-1/2=1.83 h, beta(+) gamma) or Se-75 (T-1/2 =119.8 d, beta(-) gamma). This generic model was used in conjunction with the MIRDOSE 3 computer programme to calculate radiation doses to adults; these radiation doses were compared with those calculated using compound-specific models for two [C-11]-, and eight [F-18]-labelled amino acids and [Se-75]selenomethionine. In general, the effective doses, as well as the organ and tissue doses, calculated using the generic model agreed within a factor of 2 or less, with those calculated using compound-specific models; the generic model tended to over-, rather than underestimate the organ and tissue doses. It was concluded that for C-11- and F-18-labelled amino acids and for Se-75-labelled amino acids or their analogues, the single generic biokinetic model could be applied for general radiation protection purposes. (C) 2000 Elsevier Science Ltd. All rights reserved. [References: 16]
机译:开发了一种通用的生物动力学模型,用于评估注射有C-11(T-1 / 2 = 0.34 h,beta(+),γ),F-18( T-1 / 2 = 1.83h,β(+)γ)或Se-75(T-1 / 2 = 119.8d,β(-)γ)。该通用模型与MIRDOSE 3计算机程序结合使用,可以计算出成年人的辐射剂量。将这些辐射剂量与使用化合物特异性模型计算出的两个[C-11]-和八个[F-18]标记氨基酸和[Se-75]硒代蛋氨酸的辐射剂量进行了比较。通常,使用通用模型计算的有效剂量以及器官和组织剂量与使用化合物特异性模型计算的有效剂量相差不超过2倍。通用模型倾向于高估而不是低估器官和组织的剂量。结论是,对于C-11-和F-18标记的氨基酸以及Se-75标记的氨基酸或其类似物,可以将单个通用生物动力学模型用于一般的辐射防护目的。 (C)2000 Elsevier ScienceLtd。保留所有权利。 [参考:16]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号