首页> 外文会议>Integrated modeling of complex optomechanical systems >Integration of a thermo-structural analysis with an optical model for PEPSI polarimeter
【24h】

Integration of a thermo-structural analysis with an optical model for PEPSI polarimeter

机译:PEPSI旋光仪的热结构分析与光学模型的集成

获取原文
获取原文并翻译 | 示例

摘要

The two spectropolarimeters for PEPSI (Potsdam Echelle Polarimetric and Spectroscopic Instrument) have been designed in order to reconstruct the full Stokes vector measuring linear and circular polarization simultaneously with a resolving power of 120,000. The polarimeters will be attached to the Gregorian focus of the so far largest LBT 2x8.4m telescope and will feed together with permanent focus stations the spectrograph via 44m long fibers connection. The spectrograph will be located in a pressure-temperature controlled chamber within the telescope pier. We present hereafter the last results from combined structural and CFD analyses in order to fulfill the optical requirements.
机译:设计了两种用于PEPSI的光谱偏振计(Potsdam Echelle偏振光谱仪),以重建同时测量线偏振和圆偏振的完整斯托克斯矢量,分辨力为120,000。旋光仪将连接到迄今为止最大的LBT 2x8.4m望远镜的Gregorian焦点上,并将与永久焦点站一起通过44m长的光纤连接馈入光谱仪。光谱仪将位于望远镜墩内的压力-温度控制室中。下文中,我们将结合结构和CFD分析得出最后的结果,以满足光学要求。